● When a single fan is faulty:
● The maximum operating temperature is 5°C (9°F) lower than the rated value.
● Drive performance will be aected if rear NVMe drives are congured.
● If P4 GPU cards are congured:
● The processor power consumption must be lower than 130 W if the server is
congured with six P4 GPU cards.
● The processor power consumption of the processor must be lower than 205 W if
the server is
congured with four P4 GPU cards. In addition, the P4 GPU cards
must be installed in slots: Slot 1, 2, 4, and 5.
● The server supports the maximum operating temperature of 30°C (86°F) if the P4
GPU cards are stacked and supports 35°C (95°F) if the P4 GPU cards are not
stacked.
A.3 Nameplate
Certied Model Usage Restrictions
H52H-05 Global
H52H-05-I15 India only
A.4 RAS Features
The server supports a variety of Reliability, Availability, and Serviceability (RAS)
features. You can
congure these features for better RAS.
For details about how to congure RAS features, see Huawei Server Purley
Platform BIOS Parameter Reference.
Table A-3 RAS features
Module
Feature Description
CPU Corrected Machine Check
Interrupt
Corrects error-triggered interruption.
DIMM Failed DIMM Isolation Identies a faulty DIMM and isolates it
from others before it is replaced.
Memory Thermal
Throttling
Automatically adjusts DIMM
temperatures to avoid damage due to
overheating.
Rank Sparing Allocates some memory ranks as
backup ranks to prevent the system
from crashing due to uncorrectable
errors.