Figure 4-9 Querying version information
Pay attention to the following information:
– CPLD Version: CPLD version of the compute node
– Active iBMC Version: version of the iBMC in the active work space of the
compute node
– Backup iBMC Version: version of the iBMC in the standby work space of the
compute node
3. Check whether the versions meet site requirements.
– If yes, go to Step 4.
– If no, go to Step 3.4.
4. Upgrade the iBMC, BIOS, or CPLD.
For details, see E9000 Server V100R001 Upgrade Guide.
Step 4 Query health status.
Step 5 Query alarm information.
1. Click the compute node in the specific slot and choose Alarm List.
Figure 4-10 Querying alarm information
2. Check whether any alarm is generated.
– If yes, handle the alarms.
FusionServer Pro CH121 V5 Compute Node
User Guide
4 Installation and Configuration