● Do not install the equipment in an area with strong vibration, noise, or
electromagnetic interference. The equipment shall be installed in an
environment with a magnetic eld strength less than 4 Gauss. If the magnetic
eld strength is greater than or equal to 4 Gauss, the equipment may fail to
work properly. If the magnetic eld strength is high, for example, in a
smeltery, you are advised to use a gauss meter to measure the magnetic eld
strength of the equipment installation position when the smelting equipment
is running normally.
● Ensure that the site complies with local laws, regulations, and related
standards.
● Ensure that the ground in the installation environment is solid, free from
spongy or soft soil, and not prone to subsidence. The site must not be located
in a low-lying land prone to water or snow accumulation, and the horizontal
level of the site must be above the highest water level of that area in history.
● Do not install the equipment in a position that may be submerged in water.
● Before opening doors during the installation, operation, and maintenance of
the equipment, clean up any water, ice, snow, or other foreign objects on the
top of the equipment to prevent foreign objects from falling into the
equipment.
● When installing the equipment, ensure that the installation surface is solid
enough to bear the weight of the equipment.
● After installing the equipment, remove the packing materials such as cartons,
foam, plastics, and cable ties from the equipment area.
1.4 Mechanical Safety
Ensure that all necessary tools are ready and inspected by a professional
organization. Do not use tools that have signs of scratches or fail to pass the
inspection or whose inspection validity period has expired. Ensure that the tools
are secure and not overloaded.
Do not drill holes into the equipment. Doing so may aect the sealing
performance and electromagnetic containment of the equipment and damage
components or cables inside. Metal shavings from drilling may short-circuit boards
inside the equipment.
General Requirements
● Repaint any paint scratches caused during equipment transportation or
installation in a timely manner. Equipment with scratches must not be
exposed for an extended period of time.
● Do not perform operations such as arc welding and cutting on the equipment
without evaluation by the Company.