Figure 5-8 Opening the AC maintenance compartment door
Step 3 Remove a rubber ring based on the cable diameter range. Cut o the joints
between rubber rings using scissors and then remove the rubber ring. All rubber
rings are removed in the same way.
● Remove a rubber ring strictly based on the cable diameter range and ensure that the
crimping module is not damaged. Otherwise, the IP rating of the device will be aected.
● If there is a gap between the cable and the rubber ring, prepare restop putty by
yourself and seal the gap. The restop putty shall not contain corrosive elements such
as sulfur and phosphorus. The holes and gaps shall be lled evenly and tightly.
Figure 5-9 Removing a rubber ring
Step 4 Connect the AC power cables to the terminal block and ensure that the cables are
securely connected.
The cable colors shown in the gures are for reference only. Select an appropriate cable
according to the local standards.
LUNA2000-213KTL-H0 Smart Power Control System
User Manual 5 Cable Installation
Issue 04 (2024-12-30) Copyright © Huawei Technologies Co., Ltd. 55