SUN2000 (8KTL-28KTL)
User Manual
Issue
07
Date
2014-07-30
HUAWEI TECHNOLOGIES CO., LTD.

Table of Contents

Other manuals for Huawei SUN2000-23KTL

Questions and Answers

  • K
    kennethbrewerAug 30, 2025
    Why is my Huawei SUN2000-23KTL Inverter showing Cabinet Over-Temp?
    • J
      Jean MuellerAug 30, 2025
      If the Huawei Inverter displays 'Cabinet Over-Temp', it means the inverter is installed in a place with poor ventilation. Check if the ambient temperature exceeds the upper limit. If it does, improve ventilation to decrease the temperature.
  • C
    caitlincurtisAug 29, 2025
    What causes DC Bus Voltage Fault in Huawei SUN2000-23KTL Inverter?
    • C
      carlymoonAug 29, 2025
      A DC Bus Voltage Fault on your Huawei Inverter means abnormal external conditions have triggered DC circuit protection. This can happen if the inverter input is suddenly disconnected or shielded PV strings cause a sharp change in output power (Reason ID = 3), or if the input energy can't vent quickly due to a sharp change in grid voltage (Reason ID = 9 or 11). The inverter monitors external conditions and should automatically return to normal once the fault is rectified. If the alarm occurs repeatedly, contact Huawei technical support.
  • A
    audrey37Aug 28, 2025
    What to do if Huawei SUN2000-23KTL Inverter shows Invert Module Fault?
    • J
      Jessica KellerAug 28, 2025
      The Huawei Inverter indicates an Invert Module Fault when abnormal external conditions trigger converter circuit protection inside the inverter. This could be due to a sharp drop in grid voltage or a short circuit, causing high output current (Reason ID = 4), or the inverter's output short-circuiting (Reason ID = 20). The inverter monitors external conditions and should return to normal once the issue is resolved. Check for any short circuits in the inverter's output cables and fix them.
  • S
    Stephanie RichmondAug 27, 2025
    Why is my Huawei Inverter showing a Grid Voltage Abnormal error?
    • M
      matthewreevesAug 27, 2025
      The grid voltage may be beyond the allowed range. This can happen if the grid A, B, or C phase voltage is less than the allowed range (Reason ID = 1 to 6), or if there's a power outage, a disconnected AC line, or a tripped AC circuit breaker (Reason ID = 29). If it's an accidental grid issue, the Huawei Inverter should automatically return to normal once the problem is resolved. Check if the AC voltage is normal.
  • H
    Heather LopezAug 26, 2025
    What does String 1-6 Reverse mean on Huawei SUN2000-23KTL?
    • K
      kellyhernandezAug 27, 2025
      The Huawei Inverter shows 'String 1-6 Reverse' when the cables between PV strings were connected in reverse during installation. Check if the cables between PV strings are correctly connected and reconnect them if necessary.
  • K
    kimberly67Aug 25, 2025
    How to troubleshoot Low Array Insulation Resistance on Huawei SUN2000-23KTL?
    • T
      Taylor TuckerAug 26, 2025
      The Huawei Inverter shows a Low Array Insulation Resistance error when the insulation resistance against ground of the PV strings is low, possibly due to a short circuit between PV strings and the ground. Check the insulation resistance against the ground of the PV strings and rectify any short circuit.
  • A
    Adam WrightAug 25, 2025
    What does Frequency Abnormal mean on a Huawei SUN2000-23KTL?
    • C
      Christopher KellerAug 25, 2025
      The Huawei Inverter displays a Frequency Abnormal error when the grid's actual frequency is higher or lower than the required value for the local grid. If this alarm occurs accidentally, it's possible there's an issue with the grid. The inverter will automatically revert to normal once the problem is resolved.

Summary

About This Document

Purpose

Describes the SUN2000 in terms of installation, electrical connections, commissioning, maintenance, and troubleshooting.

Intended Audience

Identifies the target users for this document as PV plant operators and qualified electrical personnel.

Symbol Conventions

Defines the safety symbols and their meanings used throughout the document.

Safety Precautions

Personnel Requirements

Defines qualifications for operating the SUN2000, emphasizing trained electrical technicians.

Identification Protection

Details importance of product labels and nameplates for secure operation.

Installation Safety

Covers safety during installation, including clearance, environment, and electrical precautions.

Overview

Introduction

Introduces the SUN2000's function, model range, and typical applications.

Appearance

Describes the physical appearance and dimensions of the SUN2000 from different views.

Symbol Conventions

Defines safety and operational symbols and nameplates used in the manual.

Monitoring Panel

Details the components of the SUN2000 monitoring panel: LCD, indicators, and buttons.

Working Principles

Explains the functional principles and internal design of the SUN2000.

Inverter Storage

Installation

Checking Before Installation

Procedures for checking packing materials and verifying deliverables are intact.

Tools

Lists required tools for installation and electrical connections, with specifications.

Determining the Installation Position

Guidelines for selecting an appropriate and safe installation location for the SUN2000.

Moving the SUN2000

Step-by-step instructions for safely moving the SUN2000, emphasizing two-person lift.

Support-mounting the SUN2000

Procedures for securing the SUN2000 to a support structure using its rear panel.

Wall-mounting the SUN2000

Detailed steps for mounting the SUN2000 onto a wall using expansion bolts.

Electrical Connections

Installing PGND Cables

Instructions for connecting the protection ground (PGND) cables for proper grounding.

Connecting AC Output Power Cables

Details on connecting the SUN2000 to the AC power distribution frame or grid.

Installing DC Input Power Cables

Steps for connecting DC input power cables from PV arrays to the SUN2000.

Connecting Communications Cables

Guide for connecting USB and RS485 communication cables for data transfer.

System Operation

Checking Before Power-On

Pre-power-on checks to ensure the SUN2000 is installed correctly and safely.

Powering on the SUN2000

Procedure for turning on the SUN2000 after all electrical connections are complete.

Setting Initialization Parameters

Guide for setting initial system language, time, and power grid standard code.

LCD

Monitoring Menu Hierarchy

Overview of the menu structure for navigating the SUN2000's LCD interface.

Monitoring Operations

Details on viewing system operating information, alarm records, and setting user parameters.

Maintenance

Powering Off the SUN2000

Procedure for safely shutting down the SUN2000 before performing maintenance.

Daily Maintenance

Routine maintenance tasks and recommended intervals for ensuring long-term operation.

Common Faults and Troubleshooting Measures

Identifies common faults and provides measures to troubleshoot and resolve them.

Inverter-Associated Operations

Removing the SUN2000

Steps for safely disconnecting and removing the SUN2000 from its installation.

Packing the SUN2000

Guidelines for packing the SUN2000 for transport or storage using original or suitable materials.

Disposing the SUN2000

Procedures for environmentally sound disposal of the SUN2000 according to local regulations.

Technical Specifications

Efficiency

Details on maximum and European efficiency ratings for different models.

Input

Technical input specifications including MPP voltage range, max input voltage, and current.

Output

Technical output specifications such as rated power, voltage, current, and frequency.

Protection

Lists built-in protection features like anti-islanding, overcurrent, and surge arresters.

Display and Communication

Information on the display type and available communication interfaces (RS485, USB).

General Data

Physical dimensions, weight, operating temperature range, and warranty information.

Standards Compliance

Lists safety, EMC, and relevant power grid standard certifications.

Quality Assurance

Warranty

Details on the product's warranty period, terms, conditions, and user requirements.

Quality Assurance Regulations

Huawei's policies regarding equipment maintenance, replacement, and returns.

Disclaimer

Lists exclusions from warranty coverage due to misoperation, incorrect installation, or unauthorized changes.

Abbreviation

Power Grid Standard Codes

Huawei SUN2000-23KTL Specifications

General IconGeneral
ModelSUN2000-23KTL
Rated Output Power23000 W
Max. DC Voltage1100 V
Maximum DC Input Voltage1100 V
Start Voltage200 V
MPPT Efficiency99.9%
Nominal AC Output Voltage400 V
Rated AC Voltage400 V
AC Output Frequency50 Hz / 60 Hz
Max Efficiency98.6%
Number of MPPTs2
Dimensions (W x H x D)600 mm x 470 mm x 210 mm
Weight30 kg
Operating Temperature Range-25 °C to +60 °C
Protection DegreeIP65
Input Voltage Range200 V - 1000 V
MPPT Voltage Range200-1000 V
Max. AC Power23000 W
Protection ClassIP65
Protection LevelIP65