EasyManuals Logo

Huawei SUN2000-30KTL-M3 User Manual

Huawei SUN2000-30KTL-M3
142 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #13 background imageLoading...
Page #13 background image
WARNING
During operations, wear personal protective equipment such as protective
clothing, insulated shoes, goggles, safety helmets, and insulated gloves.
Figure 1-1 Personal protective equipment
General Requirements
Do not stop protective devices. Pay attention to the warnings, cautions, and
related precautionary measures in this document and on the equipment.
If there is a likelihood of personal injury or equipment damage during
operations, immediately stop, report the case to the supervisor, and take
feasible protective measures.
Do not power on the equipment before it is installed or conrmed by
professionals.
Do not touch the power supply equipment directly or with conductors such as
damp objects. Before touching any conductor surface or terminal, measure
the voltage at the contact point to ensure that there is no risk of electric
shock.
Do not touch operating equipment because the enclosure is hot.
Do not touch a running fan with your hands, components, screws, tools, or
boards. Otherwise, personal injury or equipment damage may occur.
In the case of a re, immediately leave the building or the equipment area
and activate the re alarm or call emergency services. Do not enter the
aected building or equipment area under any circumstances.
Personnel Requirements
Only professionals and trained personnel are allowed to operate the
equipment.
Professionals: personnel who are familiar with the working principles and
structure of the equipment, trained or experienced in equipment
operations and are clear of the sources and degree of various potential
hazards in equipment installation, operation, maintenance
SUN2000-(20KTL, 29.9KTL, 30KTL, 36KTL, 40KTL)-
M3
User Manual 1 Safety Information
Issue 18 (2024-03-10) Copyright © Huawei Technologies Co., Ltd. 3

Table of Contents

Other manuals for Huawei SUN2000-30KTL-M3

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Huawei SUN2000-30KTL-M3 and is the answer not in the manual?

Huawei SUN2000-30KTL-M3 Specifications

General IconGeneral
ModelSUN2000-30KTL-M3
Max. DC Input Voltage1100 V
Number of MPPTs3
Rated AC Output Power30000 W
Max. Output Current47.8 A
Frequency50 Hz / 60 Hz
Adjustable Power Factor Range0.8 leading - 0.8 lagging
Total Harmonic Distortion (THD)< 3%
Max. Efficiency98.7%
European Weighted Efficiency98.4%
DC ConnectionMC4
Protection DegreeIP66
Cooling MethodNatural convection
MPPT Voltage Range200 V - 1000 V
Max. AC Output Power33000 W
Rated AC Voltage400 V
AC Voltage Range320 V - 480 V
DisplayLED Indicators
CommunicationRS485, WLAN
Operating Temperature Range-25°C to 60°C
Relative Humidity0% - 100%
Operating Altitude4000 m
Weight43 kg
Dimensions640 x 530 x 270 mm
Max. DC Input Power45000 Wp

Related product manuals