regions prone to sea breeze vary with weather conditions (such as typhoons
and monsoons) or terrains (such as dams and hills).
Installation Environment Requirements
The SUN2000 must be installed in a well-ventilated environment to ensure
good heat dissipation.
When the SUN2000 is installed under direct sunlight, the power may be
derated due to the temperature rise.
You are advised to install the SUN2000 in a sheltered place or install an
awning over it.
Mounting Structure Requirements
The mounting structure where the SUN2000 is installed must be
re resistant.
Do not install the SUN2000 on ammable building materials.
Ensure that the installation surface is solid enough to bear the weight of the
SUN2000.
In residential areas, do not install the SUN2000 on plaster board walls or
walls made of similar materials with a weak sound insulation performance
because the noise generated by the SUN2000 may interfere with residents.
Installation Angle Requirements
The SUN2000 can be wall-mounted or pole-mounted. The installation angle
requirements are as follows:
Install the SUN2000 vertically or at a maximum back tilt of 15 degrees to
facilitate heat dissipation.
Do not install the SUN2000 at forward tilted, excessive back tilted, side tilted,
horizontal, or upside down positions.
SUN2000-(2KTL-6KTL)-L1
User Manual 4 System Installation
Issue 10 (2023-02-13) Copyright © Huawei Technologies Co., Ltd. 27

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Huawei SUN2000-3KTL-L1 and is the answer not in the manual?

Huawei SUN2000-3KTL-L1 Specifications

General IconGeneral
Max. efficiency98.4%
Max. input voltage600 V
Nominal output power3000 W
Dimensions (W x H x D)365 x 365 x 156 mm
Operating temperature range-25°C to +60°C
Nominal AC voltage220 V / 230 V / 240 V
MPPT voltage range90 V - 560 V
Rated input voltage360 V
Number of MPPTs2
CoolingNatural Convection
Protection degreeIP65
Rated output voltage220 V / 230 V / 240 V
Output frequency50 Hz / 60 Hz
Power factor0.8 leading ... 0.8 lagging
THDi<3%
Efficiency98.4%
Warranty10 years
Max. apparent AC power3300 VA
Max. output power3300 W