SUN2000-(12KTL, 15KTL, 17KTL, 20KTL)-M0
User Manual
5 Electrical Connections
Copyright © Huawei Technologies Co., Ltd.
45
When routing the signal cable, ensure that it is separate from the power cable and away
from interfering sources to prevent communication from being affected.
The protection layer of the cable is in the connector. Cut off surplus core wires from the
protection layer. Ensure that the core wires are completely inserted into the cable holes,
and that the cable is securely connected.
Figure 5-17 Signal definitions
Table 5-3 Signal definitions
Pin
Definiti
on
Functio
n
Descrip
tion
Pin
Definiti
on
Functio
n
Descrip
tion
1
485A1-1
RS485
different
ial
signal+
Used to
connect
to the
RS485
signal
port on
the
SUN200
0 or
SmartLo
gger100
0A
2
485A1-2
RS485
different
ial
signal+
Used to
connect
to the
RS485
signal
port on
the
SUN200
0 or
SmartLo
gger100
0A
3
485B1-1
RS485
different
ial
signal
4
485B1-2
RS485
different
ial
signal
5
PE
Shieldin
g ground
N/A
6
PE
Shieldin
g ground
N/A
7
485A2
RS485
different
ial
signal+
Used to
connect
to an
RS485
8
DIN1
Dry
contact
interface
for grid
Connect
s to the
Ripple
Control

Table of Contents