EasyManuals Logo

Huawei SUN3KTL-L1 User Manual

Huawei SUN3KTL-L1
122 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #26 background imageLoading...
Page #26 background image
Type Tools and Instruments
Marker Steel measuring tape Level
Hydraulic pliers Heat-shrink tubing Heat gun
Personal protective
equipment (PPE)
Safety gloves Safety goggles Anti-dust mask
Safety boots
- -
4.3 Determining the Installation Position
Basic Requirements
The SUN2000 is protected to IP65 and can be installed indoors or outdoors.
Do not install the SUN2000 in a place where personnel are easy to come into
contact with its enclosure and heat sink, because these parts are extremely
hot during operation.
Do not install the SUN2000 near ammable or explosive materials.
Do not install the SUN2000 at a place within children's reach.
The SUN2000 will be corroded in salt areas, and the salt corrosion may cause
re. Do not install the SUN2000 outdoors in salt areas. A salt area refers to
the region within 500 meters from the coast or prone to sea breeze. The
regions prone to sea breeze vary with weather conditions (such as typhoons
and monsoons) or terrains (such as dams and hills).
SUN2000-(2KTL-6KTL)-L1
User Manual 4 System Installation
Issue 04 (2021-04-01) Copyright © Huawei Technologies Co., Ltd. 20

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Huawei SUN3KTL-L1 and is the answer not in the manual?

Huawei SUN3KTL-L1 Specifications

General IconGeneral
BrandHuawei
ModelSUN3KTL-L1
CategoryInverter
LanguageEnglish

Related product manuals