Category Status Description
Steady red Steady red Fault.
Communication
indicator
LED3
Blinking green at short intervals (on for 0.2s and
then o for 0.2s)
Communication is in
progress.
Blinking green at long intervals (on for 1s and
then o for 1s)
The mobile phone is
connected to the
SUN2000.
O There is no
communication.
NO TE
If the o-grid load is overloaded, indicators LED1 and LED2 on the inverter blink orange
slowly. Reduce the o-grid load power and manually clear the alarm or until the inverter is
recovered. The inverter attempts to restart at an interval of 5 minutes. If the inverter fails to
restart for three times, the interval changes to 2 hours. If the inverter is standby in o-grid
mode, check the inverter alarms and rectify the fault.
Table 6-3 LED indicators 2
Category Status Description
Device
replacement
indication
LED1 LED2 LED3
Steady red Steady red Steady red The SUN2000 hardware
is faulty. The SUN2000
needs to be replaced.
----End
SUN2000-(2KTL-6KTL)-L1
User Manual 6 System Commissioning
Issue 04 (2021-04-01) Copyright © Huawei Technologies Co., Ltd. 61

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Huawei SUN3KTL-L1 and is the answer not in the manual?

Huawei SUN3KTL-L1 Specifications

General IconGeneral
BrandHuawei
ModelSUN3KTL-L1
CategoryInverter
LanguageEnglish

Related product manuals