5.3 Transport inspection
Check delivery immediately upon receipt for completeness and possible transport damage.
5.4 Packaging
Handling packaging materials
The packaging is not taken back and must be disposed of in accordance with the respective statutory
regulations and local guidelines.
Storage of packed goods
Store in a dry and dust-free location.
If stored for longer periods (> 6 months) we recommend sealing the devices in foil,
possibly with a desiccant.
Do not expose to aggressive media.
Storage temperature: - 15 °C … +40 °C.
For storage periods longer than 6 months: Contact the manufacturer.
6 Installation and commissioning
6.1 Versions
CAUTION!
Consider chapter 2
EGS 40K standard version
1 terminal box, 2 programmable switching points, system check, switching voltage: 2 V … 30 VDC,
optional 30 … 230 VAC/DC, max. switching load 0.3 A.
EGS 40KK optional (partially redundant) version
2 terminal boxes, 2 + 2 programmable switching points, two-fold system check, switching voltage: 2 V
… 30 VDC, optional 30 … 230 VAC/DC, max. switching load 0.3 A.
EGS
®
40K… devices must only be used for the monitoring of overspeeds in safety-relevant machinery
and installations when applicable rules, regulations and laws are observed and they have to be
periodically tested. The tests must be recorded and have to be periodically tested. The tests must be
recorded and have to be evidenced (see test schedule 9.2).
Furthermore we wish to draw your attention to the relevant nationally applicable laws, regulations and
standards as well as the operating instructions that govern the safety and commissioning of individual
components and the complete installation as well as the periodically testing (electrical and mechanical
function tests).