Built on Innovation
®
9
Hidden Features and Optional Power
Feature Where Found Description
PROGRAMMABLE
SENSOR OVERRIDE
Hold – and turn to START TIMES. Sets individual stations to ignore sensor shutdowns. Select stations with
◄ or ►, use +/– to change to OFF to ignore sensor.
DELAY BETWEEN
STATIONS
Hold – and turn to RUN TIMES. Inserts a delay (seconds or minutes) between stations in a run time for
slow valves or recharging tanks.
CLIK-DELAY Hold + and turn to OFF. Set number of days for watering to remain o, aer sensor has been
activated and restored.
TOTAL RUN TIME Turn to RUN TIMES. Press ◄
when station 1 is shown, PRG to
select other programs.
Calculates and displays total of all run times in a program Start Time.
EASY RETRIEVE Hold + and PRG to Save. Hold –
and PRG to Restore.
Saves all program information to restore at a later time.
TOTAL RESET Hold PRG and press RESET
button.
Returns to factory defaults and erases watering schedule and settings.
QUICKCHECK™ +, –, ◄, ► together, then +. Checks all stations for wiring problems.
INSTALLING THE TRANSFORMER OPTIONAL
The XC Hybrid is designed to operate on batteries or a permanent
plug-in transformer, if AC power is available. A 24 VAC output plug-
in transformer can be attached to the two 24 VAC terminals inside
the lower access area.
NOTE: This does not change the DC voltage output from the station
terminals. Existing DC solenoids should remain installed.
VOLTAGE IN/OUT VERSION PART NUMBER
120/24 VAC U.S. 526500
230/24 VAC European 545700
240/24 VAC Australian 545500
TRANSFORMER MODELS