Symptom Cause Action
The product does not react
when pushing the STOP but-
ton
An object or dirt under the STOP button. Remove the object or clean under the
STOP button.
Faulty magnet or Hall sensor for the
STOP button.
Replace the STOP button. Refer to
To
replace the START/STOP button on
page 19
.
8.2.2 Symptoms during searching
Symptom Cause Action
The product runs, but the
blade disc does not rotate
The product is searching for the charging
station. The blade disc does not rotate
when the product is searching for the
charging station.
This behavior is normal and no action is
required.
8.2.3 Symptoms during docking
Symptom
Cause Action
The product detects the F sig-
nal, but cannot dock
Dirt/leaves/grass in the charging station
is preventing the product’s charging
plates from making contact with the
charging station’s contact plates.
Clean the charging station.
Malfunction in the charging station's cir-
cuit board or in the F-wire.
Replace the charging station's circuit
board. Refer to
To replace the circuit
board in the charging station on page 31
.
N signal from the antenna plate is faulty. Check N signals. Refer to
Autocheck
service tool on page 9
.
The cables for the charging plates in the
product are not connected or connected
incorrectly.
Check that the cable lugs for the charg-
ing plates are intact and properly connec-
ted. Make sure that the correct cable is
connected to the correct charging plate.
Plus and minus must be correctly con-
nected. Refer to
To replace the charging
plates on page 26
.
The cables for the contact plates in the
charging station are not connected or are
connected incorrectly.
Check that the cable lugs for the contact
plates are intact and properly connected.
Make sure that the correct cable is con-
nected to the correct charging plate. Plus
and minus must be correctly connected.
Refer to
To replace the contact plates in
the charging station on page 31
.