MAXX 450D/470/Diesel
Page 3-3
HydraMaster Corporation
02/21/06
The engine exhaust heat exchanger is bypassed, the heat will be obtained
from the engine coolant and blower exhaust heat exchangers.
8. Set the temperature to desired level.
9. If used, turn PUMP OUT switch to “ON” (switch light will be illuminated).
10. Set cleaning pressure at desired level (300 –400 psi).
11. Turn the chemical selector valve to the “PRIME” position to purge any
air from the system.
a. If the chemical does not begin to flow through the flowmeter within 60
seconds, remove the chemical PRIME line (the one without the filter)
from the chemical container and insert it into the vacuum hose connec-
tion at the front of the machine.
b. When the chemical begins to flow through the flowmeter, with the flow
indicator reading maximum flow and the PRIME line pulsing, turn the
chemical selector valve to “ON”, and place the chemical PRIME line back
into the chemical container.
c. Then, while spraying solution from the cleaning tool, adjust the chemical
flow by turning the chemical adjustment knob to the desired level.
12. Commence cleaning.
Flood Extraction
NOTE: The engine throttle has three settings: IDLE, ECONOMY, and
HIGH PERFORMANCE.
1. Start the engine with the THROTTLE switch in the “IDLE” position.
Allow the machine to run in idle for 2 - 3 minutes to warm up.
2. Connect hoses.
3. Connect wand or tool.
4. Move the THROTTLE switch to ‘HIGH PERFORMANCE” mode.
5. If used, turn PUMP OUT switch to “ON” (switch light will be illuminated).
6. Commence water extraction.
Note: Make sure the diverter and pump switch are in the “OFF” position.
10/5/01