HD3070 with Automatic Gas Console Instruction Manual 5-3
16
MAINTENANCE
Routine Maintenance
The HD3070 system is designed to require minimal regular maintenance under normal use. The following checks
are suggested to keep your system in top running condition:
Power Supply
Check the exterior for any damage. If there is damage, ensure it does not affect safe operation of the power
supply.
Remove power supply covers and inspect the interior.
Check wiring harnesses and connections for wear and damage. Check for loose connections and areas
of discoloration due to overheating.
Check for dust and foreign matter inside the unit. Blow out the unit with compressed air. In an excessively
dirty environment, do this weekly.
Blow out the fans and heat exchanger at rear of power supply. In an excessively dirty environment, do
this weekly.
At the rear of the power supply, inspect all interconnecting cables, hoses and leads for wear and damage.
Check that connections are tight but do not overtighten.
At the rear of the power supply, inspect the water filter element. A dirty filter element will be a brownish
color. Replace the filter element when it gets dirty.
Every 6 months, flush the power supply torch coolant and replace with new coolant. See Section 3, Torch
Coolant Requirements and Filling Torch Coolant System for details.
RHF Console
Check the exterior for any damage. If there is damage, ensure it does not affect safe operation of the
console.
Open the cover and inspect the interior. Check all cables and hoses for wear and damage. Check for loose
connections, areas discoloration due to overheating and plumbing leaks.
Inspect the 2 spark gaps between the electrodes. If required, clean with emery cloth, align, and regap to
0.020 ± 0.001 inch (0.51 ± 0.03 mm). Check that the electrode surfaces between the gaps are flat. If the
surfaces are rounded, replace and regap.
Check for dust and foreign matter inside the unit. Blow out the unit with compressed air. In an excessively
dirty environment, do this weekly.