5-32 HD3070 with Automatic Gas Console Instruction Manual
16
MAINTENANCE
Gas System (GS-ERR)
Error Message Error Code Description
NO ERROR 0
LOW PLASMA GAS ERR 1 This error signal is issued if the plasma gas inlet pressure is
below 105 psig (7.2 bar).
LOW SHIELD GAS ERR 2 This error signal is issued if the shield gas inlet pressure is
below 105 psig (7.2 bar).
HIGH PLASMA GAS ERR 3 This error signal is issued if the plasma gas inlet pressure is
above 135 psig (9.3 bar).
HIGH SHIELD GAS ERR 4 This error signal is issued if the shield gas inlet pressure is
above 135 psig (9.3 bar).
MV1 ERR* 5 This error signal is issued when the MV1 motor valve does
not move when commanded. When this error occurs service
is required.
MV2 ERR* 6 This error signal is issued when the MV2 motor valve does
not move when commanded. \When this error occurs service
is required.
MV3 ERR* 7 This error signal is issued when the MV3 motor valve does
not move when commanded. When this error occurs service
is required.
MV4 ERR* 8 This error signal is issued when the MV4 motor valve does
not move when commanded. When this error occurs service
is required.
MV5 ERR* 9 This error signal is issued when the MV5 motor valve does
not move when commanded. When this error occurs service
is required.
MV6 ERR* 10 This error signal is issued when the MV6 motor valve does
not move when commanded. When this error occurs service
is required.
* The plasma system will have to be powered down and then restarted if any of the motor valve errors occur.