e-2 HD3070 with Automatic Gas Console Instruction Manual
16
APPENDIX E
Introduction
This appendix will enable a technician to install the optional remote current control (RCC) to the HD3070 plasma
cutting system. The RCC has two basic components: the remote current control box (078050) and the current
setpoint cable. The RCC is interfaced with the power supply with the current setpoint cable.
Installation
1. Mount the RCC for easy access. For fixed mounting of the RCC, refer to Figure e-1.
2. Interface the RCC to the power supply with the current setpoint cable by referring to Section 3, Installation, page
3-23 and Figure 3-19 and the current setpoint cable lengths and wire run list in Figure 3-22.
WARNING
High Voltage!
Power supply must be disconnected before installation.
6-1/2 in.
(16.5 mm)
8-1/2 in.
(21.59 MM)
6-1/4 in.
(15.88 MM)
3.38 in.
(8.6 mm)
5/32 in. diameter (4 places)
(.40 mm)
1-11/64 in.
(2.98 MM)
1/2 in.
(1.27 mm)
Figure e-1 RCC Mounting Dimensions