5-30 HD3070 with Automatic Gas Console Instruction Manual
16
MAINTENANCE
Gas Console Error Messages
The gas console displays error messages for both the plasma system and gas system (Figure 5-3.1). The plasma
system and gas system messages are listed below. Following these error messages, troubleshooting flow
diagrams are provided to help resolve the problems causing the error messages.
Figure 5-3.1 Automatic Gas Console LCD Display
Indicates PS-ERR (power supply system error).
Refer to Power Supply System Error List.
Indicates GS-ERR (gas system error).
Refer to Gas System Error List.
00% 00% 00% 00% 00% 00%
INLET GAS
REMOTE or LOCAL
INLET GAS
PS-ERR GS-ERR
XXX PSI/BAR XXX PSI/BAR XXX PSI/BAR
TEST, CALIBRATE or PURGE MODE
Power Supply System (PS-ERR)
Error Message Error Code Description
NO ERROR 0
LOW COOLANT LEVEL** 1 Indicates that the coolant reservoir needs to have coolant
added.
INTERLOCK ERR** 2 This error is issued during operation when one of the
pressure or temperature switches connected to the power
distribution PCB is opened.
HOLD TIMEOUT ERR** 3 This error signal is issued if the HOLD INPUT signal was not
released within 10 seconds after the end of preflow.
NO PILOT TIMEOUT ERR** 4 This error signal is issued when the high frequency was
unable to ignite the pilot arc within 1 second.