EasyManua.ls Logo

Hypertherm HyDefinition HD3070 - Page 163

Hypertherm HyDefinition HD3070
281 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
5-38 HD3070 with Automatic Gas Console Instruction Manual
16
MAINTENANCE
PS ERR=5
PIERCE DELAY ERROR
Informs operator that PIERCE
COMPLETE signal was not received
from CNC controller within 4 seconds.
Replace cable.
Replace cable.
Correct CNC
programming for
PIERCE COMPLETE.
Replace relay PCB
1XPCB4.
Replace control PCB
1XPCB3. Fig 6-2 (4)
No
Yes
No
Yes
Was TRANSFER
signal received by
CNC controller ?
Is PS/machine
interface cable
defective ?
Fig 3-21
Is relay PCB 1XPCB4
defective ?
Fig 6-2 (1)
No
Did CNC send
PIERCE COMPLETE
signal within
4 seconds ?
Is PS/machine
interface cable
defective ?
Fig 3-21
No
Yes
No
Yes
Yes

Table of Contents

Related product manuals