OPERATION
4
4-16 HPR260 Manual Gas Instruction Manual
Mild steel
O
2
Plasma / Air Shield
260 A Cutting
Select
Gases
Set
Preflow
Set
Cutflow
Material
Thickness
Arc
Voltage
Torch-to-Work
Distance
Cutting
Speed
Initial Pierce
Height
Pierce Delay
Time
Plasma Shield Plasma Shield Plasma Shield
mm
Volts mm mm/m mm factor % seconds
O
2
Air 24 75
70 70
6
150 2.8
6500
8.5 300
0.3
10
4440
12
3850 0.4
75
75
15
155
3.6
3130
9.0 250
0.5
20
159 2170 0.6
22
166 1930 0.7
80
25
171 1685 0.8
28
170
4.8
1445
9.5 200
0.9
32
172 1135 1.0
38
174 895 1.2
44
185 580
Edge start
50
188 405
58
193 290
64
202 195
Metric
Select
Gases
Set
Preflow
Set
Cutflow
Amperage
Torch-to-Work
Distance
Marking
Speed
Arc
Voltage
Amps
mm in mm/min ipm Volts
N
2
N
2
10 10 10 10
18
2.5 0.100 6350 250 135
Marking
Select
Gases
Set
Preflow
Set
Cutflow
Material
Thickness
Arc
Voltage
Torch-to-Work
Distance
Cutting
Speed
Initial Pierce
Height
Pierce Delay
Time
Plasma Shield Plasma Shield Plasma Shield
in
Volts in mm/m in factor % seconds
O
2
Air 24 75
70 70
1/4
150 0.110
245
0.330 300
0.3
3/8
180
1/2
145 0.4
75
75
5/8
155
0.140
115
0.350 250
0.5
3/4
159 90 0.6
7/8
166 75 0.7
80
1
171 65 0.8
1-1/8
170
0.190
55
0.380 200
0.9
1-1/4
172 45 1.0
1-1/2
174 35 1.2
1-3/4
185 22
Edge start
2
188 15
2-1/4
193 12
2-1/2
202 8
English
Flow rates lpm/scfh @ 3/4" setting
O
2
Air
Preflow 0 / 0 130 / 275
Cutflow 42 / 88 104 / 220
220440220398 220435220433 220436220439

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hypertherm HyPerformance Plasma HPR260 and is the answer not in the manual?

Hypertherm HyPerformance Plasma HPR260 Specifications

General IconGeneral
Cutting Capacity Mild Steel38 mm
Output Current30-260 A
Input Voltage200-600 V, 3-PH
Gas SupplyOxygen, Air, Nitrogen
Duty Cycle260 A at 100%