100 HyPrecision Predictive waterjet pump Operator Manual 810120
5 – Preventive maintenance
Preventive maintenance
Remove the high-pressure end cap
Parts, tools, and materials
1. Remove the end cap nuts.
2. Pull the high-pressure end cap off.
3. Remove the end cap gasket.
1
2
3
4
1
Stud
2
Low-pressure water fitting
3
High-pressure end cap nut
4
High-pressure end cap
Clean towels
Isopropyl alcohol
Square drive socket, 1-1/2 inch × 3/4 inch
(included in the 1-12084 HyPrecision standard
tool kit)