HyPrecision Predictive waterjet pump Operator Manual 810120 209
9 – Installation
Installation
Do the first start
Use this procedure at installation, when putting the equipment into operation after storage or shipping, and after
maintenance or repairs are done on the intensifier, the high-pressure water system, or the low-pressure water
system.
Do a preoperation inspection
Look for leaks, deterioration, damage, or other conditions that can interfere with operation.
Look at the sight gauge on the hydraulic fluid tank. Add hydraulic fluid, if necessary.
Close all doors and replace all panels and covers, including access covers.
Make sure that all warning decals are visible and legible.
Turn on the utilities
1. Turn ON the electrical breaker.
2. Turn
ON the water to the pump.
3. Monitor for leaks.
4. Turn
ON the compressed air supply.
5. Turn
ON the electrical main.
6. Turn the primary breaker disconnect lever on the electrical enclosure door to
ON.
The operator interface screen is on when the pump is energized.
CAUTION
AIR-COOLED SYSTEM
If the COOLING IN hose and the COOLING OUT hose are not connected to the external heat
exchanger before starting the motor, the hydraulic hoses can be damaged.
If a water line, a fitting, or a valve could be frozen, do not operate the pump. Thaw the equipment
until water moves easily through the water circuit.
Do not do the first start with a diamond orifice installed. There is a possibility that the procedure
can cause damage to the orifice can during the first start.
Hypertherm recommends using a ruby orifice during the first 40 hours of operation.
Identify the source of a leak and correct the problem. Refer to Leaks on page 163.
A leak can cause damage to the water fittings.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hypertherm HyPrecision Predictive P-50S and is the answer not in the manual?

Hypertherm HyPrecision Predictive P-50S Specifications

General IconGeneral
BrandHypertherm
ModelHyPrecision Predictive P-50S
CategoryWater Pump
LanguageEnglish

Related product manuals