56 HyPrecision Predictive waterjet pump Operator Manual 810120
4 – Operation
Operation
Do a preoperation inspection
 Look for leaks, deterioration, damage, or other conditions that can interfere with operation.
 Look at the sight gauge on the hydraulic fluid tank. Add hydraulic fluid, if necessary.
 Close all doors and replace all panels and covers, including access covers.
 Make sure that all warning decals are visible and legible.
Turn on the utilities
1. Turn ON the electrical breaker.
2. Turn 
ON the water to the pump.
3. Monitor for leaks.
4. Turn 
ON the compressed air supply.
5. Turn 
ON the electrical main.
6. Turn the primary breaker disconnect lever on the electrical enclosure door to 
ON.
The operator interface screen is on when the pump is energized.
WARNING
Make sure that all connections, fasteners, locking devices, hoses, and fittings are tight.