210 HyPrecision Predictive waterjet pump Operator Manual 810120
9 – Installation
Installation
Make sure that the primary motor turns in the correct direction
1. Remove the shaft access cover.
2. Make sure that the
LOCAL/REMOTE key switch on the operation panel is set to LOCAL.
Refer to
Operator interface: Operation screens on page 58 for information.
3. Push the C
ONTROLS ON button to turn ON the control circuit in the pump.
The pump can not be turned on until the control circuit is on.
WARNING
It is necessary to have access to a turning shaft for this procedure. Do not put an object or a body
part near the shaft while the access cover is off.
CAUTION
AIR-COOLED PUMP
To prevent damage to the pump, connect the hydraulic hoses between the pump and the external
heat exchanger before doing a check of the motor direction.
CAUTION
Make sure that the primary motor turns in the correct direction before starting the pump.
If the motor turns in the opposite direction, the impeller could turn and loosen. This can cause
damage to the hydraulic pump.
1 2
1
Shaft access cover
2
Rotation arrow