HyPrecision Predictive waterjet pump Operator Manual 810120 189
8 – Pump specifications
Pump specifications
Special fittings
Incorrectly installed collar: The collar interferes with the sealing surface.
Correctly installed collar: The sealing surface is showing.
WARNING
High-pressure water fittings are designed to make a tight seal. If a fitting is installed
incorrectly, it can fail.
WARNING
Do not tighten a fitting too much. The fitting can fail.
Wrench size
Torque
N∙m lbf ∙ ft
Output adapter 1 inch 115 85
High-pressure water fittings
(gland nuts)
1/4 inch 5/8 inch 34 25
3/8 inch 13/16 inch 68 50
9/16 inch 1-3/16 inch 150 110