84 HyPrecision Predictive waterjet pump Operator Manual 810120
5 – Preventive maintenance
Preventive maintenance
Replace the hydraulic fluid
Parts, tools, and materials
Do this task when the pump is not running.
Do this every 3,000 hours.
Install a new hydraulic filter and filler-breather cap when replacing the hydraulic fluid.
Do not put too much hydraulic fluid in the tank.
3
2
1
4
1
Drain valve
2
1-14629 Filler-breather cap
3
Sight gauge
4
Access cover
1-16025 Hydraulic filter, not shown
1-17473 Hydraulic fluid service kit
Antiwear (AW) mineral oil or synthetic hydraulic
fluid, ISO viscosity grade (VG) 32 or 46
Clean towels
Isopropyl alcohol
Standard 9/16-inch open-ended wrench
(for the drain valve plug)
Standard 15/16-inch crowfoot wrench or socket
(for the access cover)
Torque wrench
Strap wrench
Hose or pipe for draining hydraulic fluid
Container for used hydraulic fluid
Recommended materials
Clean funnel

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hypertherm HyPrecision Predictive P-50S and is the answer not in the manual?

Hypertherm HyPrecision Predictive P-50S Specifications

General IconGeneral
BrandHypertherm
ModelHyPrecision Predictive P-50S
CategoryWater Pump
LanguageEnglish

Related product manuals