INSTALLATION
3-18 HySpeed HT2000LHF Instruction Manual
6
Valve Cluster Connections
See page 3-9 for plasma preflow and cutflow hose connections to the gas console.
See page 3-16 for plasma preflow and cutflow hose part numbers.
See page 3-7 for torque specifications.
1. Loosen the valve cluster screw and slide the valve cluster up the torch sleeve. Secure in place approximately as
shown in Figure 3-5.
2. Attach the plasma preflow hose from the gas console to SV4B.
3. Attach the plasma cut flow hose from the gas console to SV4A. Note that this connection is left-hand threaded.
4. Attach the 12" plasma hose from the torch to off-valve SV5. Note that this connection is left-hand threaded.
Figure 3-4 Valve Cluster Connections – Top View
20
21
Preflow SV4B
Cut Flow SV4A
Valve Cluster Screw
12" Plasma Hose from
torch to Off-Valve SV5