Torch Alignment Guide for Bevel Cutting
Powermax125 / MAXPRO200 Field Service Bulletin 811280 3
Introduction
Purpose
This Field Service Bulletin shows how to use the Hypertherm torch alignment guide accessory to do
bevel cutting on a track burner with a Powermax125 or a MAXPRO200.
Tools and materials needed
3/16 inch hexagonal key wrench
Digital level, or digital level application on a smartphone
Remote start pendant for the plasma cutting system if the track burner cannot start and stop
the plasma torch
Kit 528077 contents
Kit 528077 contains only the torch alignment guide and this Field Service Bulletin. Refer to
Figure 1.
WARNING
ELECTRIC SHOCK CAN KILL
Disconnect electrical power before doing installation or maintenance.
The line-disconnect switch must REMAIN in the OFF position until all
installation or maintenance steps are complete.
See the Safety and Compliance Manual (80669C) for more safety
information.
WARNING
EXPLOSION HAZARD CUTTING WITH FLAMMABLE OR OXIDIZING GASES
Do not use flammable or oxidizing gases with Powermax systems. These gases can cause
explosive conditions during plasma cutting operations.
An example of an oxidizing gas is oxygen. Examples of flammable gases are acetylene,
propylene, methane, and pure hydrogen. Refer to the Safety and Compliance Manual
(80669C) for more information.

Other manuals for Hypertherm Powermax 125

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hypertherm Powermax 125 and is the answer not in the manual?

Hypertherm Powermax 125 Specifications

General IconGeneral
Output Current30-125 A
Input Power15.2 kW
Open Circuit Voltage300 VDC
Gas SupplyClean, dry, oil-free air or nitrogen
Input Power Cable Length10 ft (3 m)
Rated Output Current125 A
Gas TypeAir or nitrogen
Cutting Capacity1-1/4 inch (32 mm)
Pierce Capacity1 inch (25 mm)
Input Voltage200-600 V, 3-PH
Duty Cycle100% @ 125 A
CertificationsCSA
Maximum Clean Cut Thickness1-1/4 inch (32 mm)
Cooling MethodFan-cooled
Torch OptionsHand