3.4.1 Diagnose
RDAC can remotely supervise the operation state of the repeater. Once accidental
event occurs, it will take measure immediately to ensure the repeater can work
longer.
Items would be diagnosed:
PSU Voltage
Monitor the voltage and alarm voltage in real time.
PA Temperature
Monitor the temperature in real time. Once the temperature is higher than the
specified value, an alarm will be given.
Fan State
Monitor the state of the fan in real time. Once any abnormal situation occurs, an
alarm will be given.
TX Power
Monitor the TX power in real time.
TX REF Power
Monitor the TX REF Power in real time.
VSWR
Monitor the value of VSWR in real time. Once any abnormal situation occurs, an
alarm will be given.
RX PLL State
Monitor the voltage value and the state of the RX PLL circuit. Once abnormal
situation occurs, an alarm will be given.
TX PLL State
Monitor the voltage value and the state of the TX PLL circuit. Once abnormal
situation occurs, an alarm will be given.