Basic Operation
Press any button to start the gun. The gun will shut itself off after 3 minutes of inactivity. See Figure 13
for the LITHIUM Torque Gun’s Main Screen Display. All gun parameters will be saved from the most
recent session.
Figure 13 - Main Screen Display
ANGLE
TORQUE
MULTI-COLOR
STATUS LED
BATTERY
MONITOR
FASTENER
TYPE
SOFT BUTTON
INDICATORS
Green-Ready
Yellow-Busy
Red-Error
SOFT BUTTONS
ROTATION SELECT
(TIGHTEN/LOOSEN)
RELEASE ANGLE
Setting Torque and Release Angle
Press and hold center key to toggle through screens for setting Torque, Angle and Release Angle. While
on screen, use the up and down arrow keys to select value.
Figure 14 - Setting Torque and Angle
Increase
Value
Go to Next
Screen
Decrease
Value
Soft Keys
Corresponding
to Graphic
Indicators