3. SCON-CA
95
SCON-CA outputPLC input Side (* “n” indicates the byte address of each axis.)
DO on the SCON-CA side and output data register
Position/Simplified
direct value mode 2
Half direct value
mode 2
Remote I/O node 3 Half direct value node 3
PLC input
area
(bytes)
Number of occupied
bytes:8
Number of
occupied bytes: 16
Number of occupied
bytes: 12
Number of occupied
bytes: 16
n+0, n+1 Port number 0 to 15
n+2, n+3
Current position Current position
Occupied area
Current position
n+4, n+5
Completed position
number
(simple alarm ID)
n+6, n+7 Status signal
Force feedback
data
Current position Command current
n+8, n+9
n+10, n+11
Current speed Force feedback data Current speed
n+12, n+13 Alarm code Alarm code
n+14, n+15 Status signal Status signal
n+16, n+17
n+18, n+19
n+20, n+21
n+22, n+23
n+24, n+25
n+26, n+27
n+28, n+29
n+30, n+31
(Note) The Occupied area shows the domain to be occupied with the operation mode setting.
Therefore, this domain cannot be used for any other purpose. Also, exercise caution to avoid node
address duplication.

Table of Contents

Other manuals for IAI pcon

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IAI pcon and is the answer not in the manual?

IAI pcon Specifications

General IconGeneral
Number of Axes1-4
ManufacturerIAI
CategoryController
Power Supply24 VDC
ProgrammingPC software
Communication InterfaceRS-232, RS-485
DimensionsVaries by model
Communication ProtocolsRS-232

Related product manuals