3. SCON-CA
94
SCON-CA output PLC input (* “n” indicates the byte address of each axis.)
DO on the SCON-CA side and output data register
Remote I/O
mode
Position/
Simplified direct
value mode
Half direct value
mode
Full direct value
mode
Remote I/O
mode 2
PLC output
area (bytes)
Number of
occupied bytes:
2
Number of
occupied bytes:
8
Number of
occupied bytes:
16
Number of
occupied bytes:
32
Number of
occupied bytes:
12
n+0, n+1 Port No.0 to 15 Port No.0 to 15
n+2, n+3
Current position Current position Current position
Occupied area
n+4, n+5
Completed
position No.
(simple alarm ID)
n+6, n+7 Status signal
Command
current
Command
current
Current position
n+8, n+9
n+10, n+11
Current speed Current speed
Command
current
n+12, n+13 Alarm code Alarm code
n+14, n+15 Status signal Occupied area
n+16, n+17
n+18, n+19
Force feedback
data
n+20, n+21
n+22, n+23
n+24, n+25
n+26, n+27
Occupied area
n+28, n+29 Status signal 1
n+30, n+31 Status signal 2
(Note) The Occupied area shows the domain to be occupied with the operation mode setting.
Therefore, this domain cannot be used for any other purpose. Also, exercise caution to avoid node
address duplication.

Table of Contents

Other manuals for IAI pcon

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IAI pcon and is the answer not in the manual?

IAI pcon Specifications

General IconGeneral
Number of Axes1-4
ManufacturerIAI
CategoryController
Power Supply24 VDC
ProgrammingPC software
Communication InterfaceRS-232, RS-485
DimensionsVaries by model
Communication ProtocolsRS-232

Related product manuals