3. SCON-CA
93
PLC output SCON-CA input side (* “n” indicates the byte address of each axis.)
DO on the SCON-CA side and output data register
Position/Simplified
direct value mode 2
Half direct value
mode 2
Remote I/O mode 3
Half direct value
mode 3
PLC input
area
(bytes)
Number of occupied
bytes: 8
Number of occupied
bytes: 16
Number of occupied
bytes: 12
Number of occupied
bytes: 16
n+0, n+1 Port No.0 to 15
n+2, n+3
Target position Target position Target position
n+4, n+5
Specified position
number
n+6, n+7 Control signal
Positioning band Positioning band
n+8, n+9 Speed Speed
n+10, n+11
Acceleration/
Deceleration
Occupied area
Acceleration/
Deceleration
n+12, n+13
Pressing
current-limiting
value
Pressing
current-limiting
value
n+14, n+15 Control signal Control signal
n+16, n+17
n+18, n+19
n+20, n+21
n+22, n+23
n+24, n+25
n+26, n+27
n+28, n+29
n+30, n+31
(Note) The Occupied area shows the domain to be occupied with the operation mode setting.
Therefore, this domain cannot be used for any other purpose. Also, exercise caution to avoid node
address duplication.

Table of Contents

Other manuals for IAI pcon

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IAI pcon and is the answer not in the manual?

IAI pcon Specifications

General IconGeneral
Number of Axes1-4
ManufacturerIAI
CategoryController
Power Supply24 VDC
ProgrammingPC software
Communication InterfaceRS-232, RS-485
DimensionsVaries by model
Communication ProtocolsRS-232

Related product manuals