58
007 -
The system configuration report shows only those devices
supported by the diagnostics diskette.
If a device is missing from the list and is not factory installed,
refer to the service manual provided for that device.
008 - DOES THE DIAGNOSTICS FINISH WITHOUT ANY
ERRORS? (YES, READ AHEAD. NO, GO TO STEP
009.)
q
If the Diagnostics \ All Tests did not detect a failure but
the system still indicates a failure:
q
Check all adapter card jumper settings.
q
Check all adapter card switch settings.
q
Check all adapter card cables and connectors.
q
Make sure that all of the above are set correctly and
show the correct voltages and continuity. Replace any
defective cables or adapter cards. See “Power Supply
Cable Connector Specifications” on page 137 and the
layout of system board according the machine type in
chapter 5.
q
Run the Diagnostics \ All Tests again.
q
If an error or other symptom is displayed, go to “Index of
Symptoms, Messages, Error Codes, or Beeps” on page
59.
q
If no error can be detected or the symptom is
intermittent, go to "Undetermined Problems” on page 93.
q
End
009 -
q
If the last test stops and you cannot continue, first make
sure all switches, power connectors, cables, and
jumpers are set correctly and show the correct voltages
and continuity.
q
Take note of any messages, error codes, beeps, or new
symptoms. Go to "Index of Symptoms, Messages, Error
Codes, or Beeps" on page 59.
q
If there is no error symptom or the error symptom is
intermittent, go to “Undetermined Problems” on page 93.