Appendix B. Run-time switching software default settings
Table 7 contains the default settings for the run-time switching software variables.
Table 7. Default settings for run-time switching software variables
Variable Default value
Load mode Ethernet
Configuration update Disable
Firmware update Disable
Out-of-band baud rate 9600
IP address 192.168.70.1xx, where xx depends on the
number of the bay into which you have
installed the switch module, as shown in
Table 1 on page 19
Subnet mask 255.0.0.0
Default gateway 0.0.0.0
BOOTP service Disable
TFTP server IP address 0.0.0.0
Auto log-out 10 min
User name None
Password None
MAC address aging time 300 secs
IGMP snooping Disable
Switch GVRP Disable
Telnet status Enable
Web status Enable
Device STP Disable
Port STP Enable
Port enable Enable
Scheduling mechanism for COS queues Strict
Trunk load sharing algorithm Src address
Bridge max age 20 secs
Bridge hello time 2 secs
Bridge forward delay 15 secs
Bridge priority 32768
Port STP cost 100
Port STP priority 128
NWay Enable
Flow control Enable
Community string “public”, “private”
VLAN mode IEEE 802.1Q
Default port VID 1
Ingress rule checking Disable
© Copyright IBM Corp. 2002 117