Installing an I/O expansion adapter
Use this information to install an I/O expansion adapter.
Before you begin
Before you install an I/O expansion adapter, complete the following steps:
1. Read “Safety” on page v and “Installation guidelines” on page 487.
2. If the compute node is installed in an IBM Flex System chassis, remove it (see
“Removing a compute node from a chassis” on page 489 for instructions).
3. Carefully lay the compute node on a flat, static-protective surface, orienting the
compute node with the bezel pointing toward you.
About this task
This component can be installed as an optional device or as a CRU. The
installation procedure is the same for the optional device and the CRU.
Procedure
To install an I/O expansion adapter, complete the following steps.
Expansion
cover
Adapter
1. Remove the cover (see “Removing the compute node cover” on page 498).
2. Locate the I/O expansion connectors (see “System-board connectors” on page
16).
3. Remove the expansion cover ▌1▐ from the connector, if one is present.
4. Touch the static-protective package that contains the adapter to any unpainted
metal surface on the IBM Flex System chassis or any unpainted metal surface on
any other grounded rack component; then, remove the adapter from the
package.
5. Open the retention clips if they are closed.
6. Orient the connector on the expansion adapter with the I/O expansion
connector and alignment pins on the system board ▌2▐; then, press the adapter
into the I/O expansion connector.
7. Firmly press on the indicated locations to seat the expansion adapter in the
connector and over the alignment pins.
8. Close the retention clips ▌3▐.
What to do next
After you install the I/O expansion adapter, complete the following steps:
Chapter 7. Installing, removing, and replacing compute node components 525

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM Flex System x440 Compute Node and is the answer not in the manual?

IBM Flex System x440 Compute Node Specifications

General IconGeneral
BrandIBM
ModelFlex System x440 Compute Node
CategoryServer
LanguageEnglish

Related product manuals