Table 25. 101-711 through FFC-725 SRNs (continued)
SRN FFC Description and Action
252B-719 252B Device bus termination power lost or not detected.
1. Check the BladeCenter management-module event log. If an error was recorded
by the system, see “POST progress codes (checkpoints)” on page 84.
2. Replace any parts reported by the diagnostic program.
3. Replace the system-board.
252B-720 252B Adapter detected device bus failure.
1. Check the BladeCenter management-module event log. If an error was recorded
by the system, see “POST progress codes (checkpoints)” on page 84.
2. Replace any parts reported by the diagnostic program.
3. Replace the system-board.
252B-721 252B Temporary adapter detected device bus failure.
1. Check the BladeCenter management-module event log. If an error was recorded
by the system, see “POST progress codes (checkpoints)” on page 84.
2. Replace any parts reported by the diagnostic program.
3. Replace the system-board.
252B-722 252B Device bus interface problem.
1. Check the BladeCenter management-module event log. If an error was recorded
by the system, see “POST progress codes (checkpoints)” on page 84.
2. Replace any parts reported by the diagnostic program.
3. Replace the system-board.
252B-723 252B Device bus interface problem.
1. Check the BladeCenter management-module event log. If an error was recorded
by the system, see “POST progress codes (checkpoints)” on page 84.
2. Replace any parts reported by the diagnostic program.
3. Replace the system-board.
254E-201 254E 221 Adapter configuration error. Go to “Performing the checkout procedure” on page
184.
254E-601 254 Error log analysis indicates adapter failure. Go to “Performing the checkout
procedure” on page 184.
254E-602 254 Error log analysis indicates an error attention condition. Go to “Performing the
checkout procedure” on page 184.
254E-603 254 Error log analysis indicates that the microcode could not be loaded on the adapter.
Go to “Performing the checkout procedure” on page 184.
254E-604 254 Error log analysis indicates a permanent adapter failure. Go to “Performing the
checkout procedure” on page 184.
254E-605 254 Error log analysis indicates permanent adapter failure is reported on the other port
of this adapter. Go to “Performing the checkout procedure” on page 184.
254E-606 254 Error log analysis indicates adapter failure. Go to “Performing the checkout
procedure” on page 184.
254E-701 254E 221 Error log analysis indicates permanent adapter failure. Go to “Performing the
checkout procedure” on page 184.
254E-702 254E 221 Error log analysis indicates permanent adapter failure is reported on the other port
of this adapter. Go to “Performing the checkout procedure” on page 184.
2567-xxx 2567 USB integrated system-board and chassis assembly. Go to “Performing the checkout
procedure” on page 184.
144 Power Systems: Problem Determination and Service Guide for the IBM Power PS700 (8406-70Y)