EasyManuals Logo

IBM Power PS700 Problem Determination And Service Guide

IBM Power PS700
294 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #230 background imageLoading...
Page #230 background image
Isolating firmware problems
You can use this procedure to isolate firmware problems.
To isolate a firmware problem, follow the procedure until the problem is solved.
1. If the blade server is operating, shut down the operating system and turn off the blade server.
2. Turn on the blade server.
If the problem no longer occurs, no further action is necessary. You are finished with this procedure.
3. If the blade server boots up far enough to allow the installation of server firmware updates, check for
appropriate updates and install them.
If you install updates, reboot the server and see if the problem still exists. If not, you are finished with
this procedure.
4. Recover the system firmware, as described in “Recovering the system firmware” on page 220.
5. After recovering the system firmware, check for and install any server firmware updates.
Save vfchost map data
Before you replace physical components on your blade server, it might be necessary to first save the
original virtual Fibre Channel vfchost data of your blade server.
To save the original vfchost data and the original physical Fibre Channel adapter port (fcs) location codes,
complete the following steps by using the padmin user account:
1. To save the original vfchost data, use the lsmap command as follows. Enter the command from the
command-line interface on the source Virtual I/O Server (VIOS):
lsmap -all -npiv | tee lsmap_OUTPUT_before
The output might look like the following example:
Name Physloc ClntID ClntName ClntOS
--------------- ---------------------------------------- ------- ---------- ------
vfchost1 U7895.42X.9999999-V1-C32 3
Status NOT_LOGGED_IN
FC name fcs1 FC loc code:U78AF.001.startSN-P1-C35-L1-T2
Ports logged in 0
Flags 4<NOT_LOGGED>
VFC client name VFC client DRC
Name Physloc ClntID ClntName ClntOS
--------------- ---------------------------------------- ------- ---------- ------
vfchost2 U7895.42X.9999999-V1-C33 4 cli_lpar_1 AIX
Status LOGGED_IN
FC name fcs0 FC loc code:U78AF.001.startSN-P1-C35-L1-T1
Ports logged in 1
Flags a<LOGGED_IN,STRIP_MERGE>
VFC client name fcs1 VFC client DRC:U9999.999.9999999-V4-C32-T1
In this example, the original serial number is represented as startSN.
218 Power Systems: Problem Determination and Service Guide for the IBM Power PS700 (8406-70Y)

Table of Contents

Other manuals for IBM Power PS700

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM Power PS700 and is the answer not in the manual?

IBM Power PS700 Specifications

General IconGeneral
BrandIBM
ModelPower PS700
CategoryServer
LanguageEnglish

Related product manuals