Table 27. A00-FF0 through A24-xxx SRNs (continued)
SRN Description FRU/action
A24-xxx Spurious interrupts have exceeded
threshold.
1. Check the BladeCenter management-module
event log; if an error was recorded by the
system, see “POST progress codes
(checkpoints)” on page 84.
2. Replace part numbers reported by the
diagnostic program.
3. If no entry is found, Replace the
system-board.
SCSD Devices SRNs (ssss-102 to ssss-640)
These service request numbers (SRNs) identify a Self-Configuring SCSI Device (SCSD) problem.
Use Table 28 to identify an SRN when you suspect a SAS hard disk device problem. Replace the parts in
the order that the failing function codes (FFCs) are listed.
Notes:
1. Some SRNs might have 4 digits rather than 3 digits after the dash (–).
2. The ssss before the dash (–) represents the 3 digit or 4 digit SCSD SRN.
Table 28. ssss-102 through ssss-640 SRNs
SRN FFC Description and action
ssss-102 ssss An unrecoverable media error occurred.
1. Check the BladeCenter management-module event log. If an error was recorded
by the system, see “POST progress codes (checkpoints)” on page 84.
2. Replace any parts reported by the diagnostic program.
3. Replace the system board and chassis assembly, as described in “Replacing the
FRU system-board and chassis assembly” on page 260.
ssss-104 ssss The motor failed to restart.
1. Check the BladeCenter management-module event log. If an error was recorded
by the system, see “POST progress codes (checkpoints)” on page 84.
2. Replace any parts reported by the diagnostic program.
3. Replace the system board and chassis assembly, as described in “Replacing the
FRU system-board and chassis assembly” on page 260.
ssss-105 ssss The drive did not become ready.
1. Check the BladeCenter management-module event log. If an error was recorded
by the system, see “POST progress codes (checkpoints)” on page 84.
2. Replace any parts reported by the diagnostic program.
3. Replace the system board and chassis assembly, as described in “Replacing the
FRU system-board and chassis assembly” on page 260.
ssss-106 ssss The electronics card test failed.
1. Check the BladeCenter management-module event log. If an error was recorded
by the system, see “POST progress codes (checkpoints)” on page 84.
2. Replace any parts reported by the diagnostic program.
3. Replace the system board and chassis assembly, as described in “Replacing the
FRU system-board and chassis assembly” on page 260.
Chapter 2. Diagnostics 177

Table of Contents

Other manuals for IBM Power PS700

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM Power PS700 and is the answer not in the manual?

IBM Power PS700 Specifications

General IconGeneral
BrandIBM
ModelPower PS700
CategoryServer
LanguageEnglish

Related product manuals