EasyManuals Logo

IBM Power PS700 Problem Determination And Service Guide

IBM Power PS700
294 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #41 background imageLoading...
Page #41 background image
B200xxxx Logical partition SRCs
A B200xxxx SRC is a logical partition reference code that is related to logical partitioning.
Table 14 describes system reference codes that might be displayed if system firmware detects a problem.
Suggested actions to correct the problem are also listed.
Note: For problems persisting after completing the suggested actions, see “Checkout procedure” on page
184 and “Solving undetermined problems” on page 227.
Table 14. B200xxxx Logical partition SRCs
v Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved. If an action solves the problem, then you can stop performing the remaining actions.
v See Chapter 3, “Parts listing, Type 8406,” on page 229 to determine which components are CRUs and which
components are FRUs.
B200 xxxx
Reference Code Description Action
B2001130 A problem occurred during the
migration of a partition
You attempted to migrate a partition
to a system that has a power or
thermal problem. The migration will
not continue.
Look for and fix power or thermal problems and then
retry the migration.
B2001131 A problem occurred during the
migration of a partition.
The migration of a partition did not
complete.
Check for server firmware updates; then, install the
updates if available.
B2001132 A problem occurred during the
startup of a partition.
A platform firmware error occurred
while it was trying to allocate
memory. The startup will not
continue.
Collect a platform dump and then go to “Isolating
firmware problems” on page 218.
B2001133 A problem occurred during the
migration of a partition.
The migration of a partition did not
complete.
Check for server firmware updates; then, install the
updates if available.
B2001134 A problem occurred during the
migration of a partition.
The migration of a partition did not
complete.
Check for server firmware updates; then, install the
updates if available.
B2001140 A problem occurred during the
migration of a partition.
The migration of a partition did not
complete.
Check for server firmware updates; then, install the
updates if available.
B2001141 A problem occurred during the
migration of a partition.
The migration of a partition did not
complete.
Check for server firmware updates; then, install the
updates if available.
Chapter 2. Diagnostics 29

Table of Contents

Other manuals for IBM Power PS700

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM Power PS700 and is the answer not in the manual?

IBM Power PS700 Specifications

General IconGeneral
BrandIBM
ModelPower PS700
CategoryServer
LanguageEnglish

Related product manuals