D1xx900C to D1xxC003 Service processor power-off checkpoints
These D1xx service processor power-off status codes offer information about the status of the service
processor during a power-off operation.
Table 24 lists the progress codes that might be displayed during the power-on self-test (POST), along with
suggested actions to take if the system hangs on the progress code. Only when you experience a hang
condition should you take any of the actions described for a progress code.
Table 24. D1xx900C to D1xxC003 checkpoints
v If the system hangs on a progress code, follow the suggested actions in the order in which they are listed in
the Action column until the problem is solved. If an action solves the problem, you can stop performing the
remaining actions.
v See Chapter 3, “Parts listing, Type 8406,” on page 229 to determine which components are CRUs and which
components are FRUs.
Progress code
Description
(Command Being Processed) Action
D1xx900C Breakpoint set in CPU controls has been
hit
1. Go to “Checkout procedure” on page 184.
2. Replace the system-board, as described in
“Replacing the FRU system-board and
chassis assembly” on page 260.
D1xxB0FF Request to initiate power-off program
has been sent
1. Go to “Checkout procedure” on page 184.
2. Replace the system-board, as described in
“Replacing the FRU system-board and
chassis assembly” on page 260.
D1xxC000 Indicates a message is ready to send to
the hypervisor to power off
1. Go to “Checkout procedure” on page 184.
2. Replace the system-board, as described in
“Replacing the FRU system-board and
chassis assembly” on page 260.
D1xxC001 Waiting for the hypervisor to
acknowledge the delayed power off
notification
1. Go to “Checkout procedure” on page 184.
2. Replace the system-board, as described in
“Replacing the FRU system-board and
chassis assembly” on page 260.
D1xxC002 Waiting for the hypervisor to send the
power off message
1. Go to “Checkout procedure” on page 184.
2. Replace the system-board, as described in
“Replacing the FRU system-board and
chassis assembly” on page 260.
D1xxC003 Hypervisor handshaking is complete
1. Go to “Checkout procedure” on page 184.
2. Replace the system-board, as described in
“Replacing the FRU system-board and
chassis assembly” on page 260.
128 Power Systems: Problem Determination and Service Guide for the IBM Power PS700 (8406-70Y)

Table of Contents

Other manuals for IBM Power PS700

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM Power PS700 and is the answer not in the manual?

IBM Power PS700 Specifications

General IconGeneral
BrandIBM
ModelPower PS700
CategoryServer
LanguageEnglish

Related product manuals