Table 15. B700xxxx Licensed internal code SRCs (continued)
v Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved. If an action solves the problem, then you can stop performing the remaining actions.
v See Chapter 3, “Parts listing, Type 8406,” on page 229 to determine which components are CRUs and which
components are FRUs.
B700 xxxx Error Codes Description Action
F106 System firmware detected an error Replace the system-board and chassis
assembly, as described in “Replacing the FRU
system-board and chassis assembly” on page
260.
F107 System firmware detected an error.
1. Collect the event log information.
2. Go to “Isolating firmware problems” on
page 218.
F108 A firmware error caused the system to
terminate.
1. Collect the event log information.
2. Go to “Isolating firmware problems” on
page 218.
F10A System firmware detected an error Look for and correct B1xxxxxx errors.
F10B A processor resource has been disabled
due to hardware problems
Replace the system-board and chassis
assembly, as described in “Replacing the FRU
system-board and chassis assembly” on page
260.
F10C The platform LIC detected an internal
problem performing Partition Mobility.
1. Collect the event log information.
2. Go to “Isolating firmware problems” on
page 218.
F120 Informational system log entry only. No corrective action is required.
F130 Thermal Power Management Device
firmware error was detected.
Check for server firmware updates; then,
install the updates if available.
BA000010 to BA400002 Partition firmware SRCs
The power-on self-test (POST) might display an error code that the partition firmware detects.
Table 16 describes error codes that might be displayed if POST detects a problem. The description also
includes suggested actions to correct the problem.
Note: For problems persisting after completing the suggested actions, see “Checkout procedure” on page
184 and “Solving undetermined problems” on page 227.
Table 16. BA000010 to BA400002 Partition firmware SRCs
v Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved. If an action solves the problem, then you can stop performing the remaining actions.
v See Chapter 3, “Parts listing, Type 8406,” on page 229 to determine which components are CRUs and which
components are FRUs.
Error code Description Action
BA000010 The device data structure is corrupted
1. Go to “Checkout procedure” on page 184.
2. Replace the system-board, as described in
“Replacing the FRU system-board and
chassis assembly” on page 260.
48 Power Systems: Problem Determination and Service Guide for the IBM Power PS700 (8406-70Y)

Table of Contents

Other manuals for IBM Power PS700

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM Power PS700 and is the answer not in the manual?

IBM Power PS700 Specifications

General IconGeneral
BrandIBM
ModelPower PS700
CategoryServer
LanguageEnglish

Related product manuals