A00-FF0 through A24-xxx SRNs
AIX might generate service request numbers (SRNs) from A00-FF0 to A24-xxx.
Note: Some SRNs in this sequence might have 4 rather than 3 digits after the dash (–).
Table 26 shows the meaning of an x in any of the following SRNs, such as A01-00x.
Table 26. Meaning of the last character (x) after the hyphen
Number Meaning
1 Replace all FRUs listed
2 Hot swap supported
4 Software might be the cause
8 Reserved
Table 27 describes each SRN and provides a recommended corrective action.
Table 27. A00-FF0 through A24-xxx SRNs
SRN Description FRU/action
A00-FF0 Error log analysis is unable to
determine the error. The error log
indicates the following physical FRU
locations as the probable causes.
1. Check the BladeCenter management-module
event log; if an error was recorded by the
system, see “POST progress codes
(checkpoints)” on page 84.
2. If no entry is found, Replace the
system-board.
A01-00x Error log analysis indicates an error
detected by the microprocessor, but the
failure could not be isolated.
1. Check the BladeCenter management-module
event log; if an error was recorded by the
system, see “POST progress codes
(checkpoints)” on page 84.
2. If no entry is found, Replace the
system-board.
A01-01x GCPU internal error.
1. Check the BladeCenter management-module
event log; if an error was recorded by the
system, see “POST progress codes
(checkpoints)” on page 84.
2. If no entry is found, Replace the
system-board.
A01-02x CPU internal cache or cache controller
error.
1. Check the BladeCenter management-module
event log; if an error was recorded by the
system, see “POST progress codes
(checkpoints)” on page 84.
2. If no entry is found, Replace the
system-board.
A01-05x System bus time-out error.
1. Check the BladeCenter management-module
event log; if an error was recorded by the
system, see “POST progress codes
(checkpoints)” on page 84.
2. If no entry is found, Replace the
system-board.
Chapter 2. Diagnostics 157