Table 27. A00-FF0 through A24-xxx SRNs (continued)
SRN Description FRU/action
A1D-34x A non-critical error has been detected:
Wire Test Error.
1. Check the BladeCenter management-module
event log; if an error was recorded by the
system, see “POST progress codes
(checkpoints)” on page 84.
2. If no entry is found, Replace the
system-board.
A1D-35x A non-critical error has been detected:
Mainstore or Cache IPL Diagnostic
Error.
1. Check the BladeCenter management-module
event log; if an error was recorded by the
system, see “POST progress codes
(checkpoints)” on page 84.
2. If no entry is found, Replace the
system-board.
A1D-37x A non-critical error has been detected:
Clock or PLL Error.
1. Check the BladeCenter management-module
event log; if an error was recorded by the
system, see “POST progress codes
(checkpoints)” on page 84.
2. If no entry is found, Replace the
system-board.
A1D-38x A non-critical error has been detected:
Hardware Scan or Initialization Error.
1. Check the BladeCenter management-module
event log; if an error was recorded by the
system, see “POST progress codes
(checkpoints)” on page 84.
2. If no entry is found, Replace the
system-board.
A1D-40x A non-critical error has been detected:
Presence/Detect Error (Mis-Plugged).
1. Check the BladeCenter management-module
event log; if an error was recorded by the
system, see “POST progress codes
(checkpoints)” on page 84.
2. If no entry is found, Replace the
system-board.
A1D-50x Recoverable errors on resource indicate
a trend toward an unrecoverable error.
However, the resource could not be
deconfigured and is still in use. The
system is operating with the potential
for an unrecoverable error.
1. If repair is not immediately available, reboot
and the resource will be deconfigured;
operations can continue in a degraded mode.
2. Check the BladeCenter management-module
event log; if an error was recorded by the
system, see “POST progress codes
(checkpoints)” on page 84.
3. If no entry is found, Replace the
system-board.
A24-000 Spurious interrupts on shared interrupt
level have exceeded threshold
1. Check the BladeCenter management-module
event log. If an error was recorded by the
system, see “POST progress codes
(checkpoints)” on page 84.
2. Replace part numbers reported by the
diagnostic program.
3. If no entry is found, Replace the
system-board.
176 Power Systems: Problem Determination and Service Guide for the IBM Power PS700 (8406-70Y)

Table of Contents

Other manuals for IBM Power PS700

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM Power PS700 and is the answer not in the manual?

IBM Power PS700 Specifications

General IconGeneral
BrandIBM
ModelPower PS700
CategoryServer
LanguageEnglish

Related product manuals