EasyManua.ls Logo

IBM Power PS700 - Page 162

IBM Power PS700
294 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Table 25. 101-711 through FFC-725 SRNs (continued)
SRN FFC Description and Action
2E10-605 2E10 Error Log Analysis indicates permanent adapter failure is reported on the other port
of this adapter.
1. Check the BladeCenter management-module event log. If an error was recorded
by the system, see “POST progress codes (checkpoints)” on page 84.
2. Replace any parts reported by the diagnostic program.
3. Replace the system-board.
2E10-606 2E10 Error Log Analysis indicates adapter failure.
1. Check the BladeCenter management-module event log. If an error was recorded
by the system, see “POST progress codes (checkpoints)” on page 84.
2. Replace any parts reported by the diagnostic program.
3. Replace the system-board.
2E10-701 2E10 221 Error Log Analysis indicates permanent adapter failure.
1. Check the BladeCenter management-module event log. If an error was recorded
by the system, see “POST progress codes (checkpoints)” on page 84.
2. Replace any parts reported by the diagnostic program.
3. Replace the system-board.
2E10-702 2E10 221 Error Log Analysis indicates permanent adapter failure.
1. Check the BladeCenter management-module event log. If an error was recorded
by the system, see “POST progress codes (checkpoints)” on page 84.
2. Replace any parts reported by the diagnostic program.
3. Replace the system-board.
2E13-201 2E13 221 Adapter configuration error.
1. Check the BladeCenter management-module event log. If an error was recorded
by the system, see “POST progress codes (checkpoints)” on page 84.
2. Replace any parts reported by the diagnostic program.
3. Replace the system-board.
2E13-601 2E13 Error Log Analysis indicates adapter failure.
1. Check the BladeCenter management-module event log. If an error was recorded
by the system, see “POST progress codes (checkpoints)” on page 84.
2. Replace any parts reported by the diagnostic program.
3. Replace the system-board.
2E13-602 2E13 Error Log Analysis indicates an Error Attention condition.
1. Check the BladeCenter management-module event log. If an error was recorded
by the system, see “POST progress codes (checkpoints)” on page 84.
2. Replace any parts reported by the diagnostic program.
3. Replace the system-board.
2E13-603 2E13 Error Log Analysis indicates that the microcode could not be loaded on the adapter.
1. Check the BladeCenter management-module event log. If an error was recorded
by the system, see “POST progress codes (checkpoints)” on page 84.
2. Replace any parts reported by the diagnostic program.
3. Replace the system-board.
2E13-604 2E13 Error Log Analysis indicates a permanent adapter failure.
1. Check the BladeCenter management-module event log. If an error was recorded
by the system, see “POST progress codes (checkpoints)” on page 84.
2. Replace any parts reported by the diagnostic program.
3. Replace the system-board.
150 Power Systems: Problem Determination and Service Guide for the IBM Power PS700 (8406-70Y)

Table of Contents

Other manuals for IBM Power PS700

Related product manuals