Table 25. 101-711 through FFC-725 SRNs (continued)
SRN FFC Description and Action
2E14-605 2E14 Error Log Analysis indicates permanent adapter failure is reported on the other port
of this adapter.
1. Check the BladeCenter management-module event log. If an error was recorded
by the system, see “POST progress codes (checkpoints)” on page 84.
2. Replace any parts reported by the diagnostic program.
3. Replace the system-board.
2E14-606 2E14 Error Log Analysis indicates adapter failure.
1. Check the BladeCenter management-module event log. If an error was recorded
by the system, see “POST progress codes (checkpoints)” on page 84.
2. Replace any parts reported by the diagnostic program.
3. Replace the system-board.
2E14-701 2E14 221 Error Log Analysis indicates permanent adapter failure.
1. Check the BladeCenter management-module event log. If an error was recorded
by the system, see “POST progress codes (checkpoints)” on page 84.
2. Replace any parts reported by the diagnostic program.
3. Replace the system-board.
2E14-702 2E14 221 Error Log Analysis indicates permanent adapter failure is reported
1. Check the BladeCenter management-module event log. If an error was recorded
by the system, see “POST progress codes (checkpoints)” on page 84.
2. Replace any parts reported by the diagnostic program.
3. Replace the system-board.
2E15-201 2E15 221 Adapter configuration error.
1. Check the BladeCenter management-module event log. If an error was recorded
by the system, see “POST progress codes (checkpoints)” on page 84.
2. Replace any parts reported by the diagnostic program.
3. Replace the system-board.
2E15-601 2E15 Error Log Analysis indicates adapter failure.
1. Check the BladeCenter management-module event log. If an error was recorded
by the system, see “POST progress codes (checkpoints)” on page 84.
2. Replace any parts reported by the diagnostic program.
3. Replace the system-board.
2E15-602 2E15 Error Log Analysis indicates an Error Attention condition.
1. Check the BladeCenter management-module event log. If an error was recorded
by the system, see “POST progress codes (checkpoints)” on page 84.
2. Replace any parts reported by the diagnostic program.
3. Replace the system-board.
2E15-603 2E15 Error Log Analysis indicates that the microcode could not be loaded on the adapter.
1. Check the BladeCenter management-module event log. If an error was recorded
by the system, see “POST progress codes (checkpoints)” on page 84.
2. Replace any parts reported by the diagnostic program.
3. Replace the system-board.
2E15-604 2E15 Error Log Analysis indicates a permanent adapter failure.
1. Check the BladeCenter management-module event log. If an error was recorded
by the system, see “POST progress codes (checkpoints)” on page 84.
2. Replace any parts reported by the diagnostic program.
3. Replace the system-board.
152 Power Systems: Problem Determination and Service Guide for the IBM Power PS700 (8406-70Y)