Table 25. 101-711 through FFC-725 SRNs (continued)
SRN FFC Description and Action
2E21-605 2E21 Error Log Analysis indicates permanent adapter failure is reported on the other port
of this adapter.
1. Check the BladeCenter management-module event log. If an error was recorded
by the system, see “POST progress codes (checkpoints)” on page 84.
2. Replace any parts reported by the diagnostic program.
3. Replace the system-board.
2E21-606 2E21 Error Log Analysis indicates adapter failure.
1. Check the BladeCenter management-module event log. If an error was recorded
by the system, see “POST progress codes (checkpoints)” on page 84.
2. Replace any parts reported by the diagnostic program.
3. Replace the system-board.
2E21-701 2E21 221 Error Log Analysis indicates permanent adapter failure.
1. Check the BladeCenter management-module event log. If an error was recorded
by the system, see “POST progress codes (checkpoints)” on page 84.
2. Replace any parts reported by the diagnostic program.
3. Replace the system-board.
2E21-702 2E21 221 Error Log Analysis indicates permanent adapter failure is reported on the other port
of this adapter.
1. Check the BladeCenter management-module event log. If an error was recorded
by the system, see “POST progress codes (checkpoints)” on page 84.
2. Replace any parts reported by the diagnostic program.
3. Replace the system-board.
2E23-101 2E23 Register Test Failure
1. Check the BladeCenter management-module event log. If an error was recorded
by the system, see “POST progress codes (checkpoints)” on page 84.
2. Replace any parts reported by the diagnostic program.
3. Replace the system-board.
2E23-102 2E23 VPD Checksum Test Failure
1. Check the BladeCenter management-module event log. If an error was recorded
by the system, see “POST progress codes (checkpoints)” on page 84.
2. Replace any parts reported by the diagnostic program.
3. Replace the system-board.
2E23-103 2E23 Flash Test Failure
1. Check the BladeCenter management-module event log. If an error was recorded
by the system, see “POST progress codes (checkpoints)” on page 84.
2. Replace any parts reported by the diagnostic program.
3. Replace the system-board.
2E23-104 2E23 Internal Wrap Test Failure
1. Check the BladeCenter management-module event log. If an error was recorded
by the system, see “POST progress codes (checkpoints)” on page 84.
2. Replace any parts reported by the diagnostic program.
3. Replace the system-board.
2E23-105 2E23 External Wrap Test Failure
1. Check the BladeCenter management-module event log. If an error was recorded
by the system, see “POST progress codes (checkpoints)” on page 84.
2. Replace any parts reported by the diagnostic program.
3. Replace the system-board.