Table 27. A00-FF0 through A24-xxx SRNs (continued)
SRN Description FRU/action
A05-06x System shutdown due to abnormally
high internal temperature.
1. Make sure that:
a. The room ambient temperature is within
the system operating environment.
b. There is unrestricted air flow around the
system.
c. All system covers are closed.
d. There are no fan failures
2. Check the BladeCenter management-module
event log; if an error was recorded by the
system, see “POST progress codes
(checkpoints)” on page 84.
3. If no entry is found, Replace the
system-board.
A05-07x Sensor indicates a power supply has
failed.
1. Check the BladeCenter management-module
event log; if an error was recorded by the
system, see “POST progress codes
(checkpoints)” on page 84.
2. If no entry is found, Replace the
system-board.
A05-08x System shutdown due to power supply
failure.
1. Check the BladeCenter management-module
event log; if an error was recorded by the
system, see “POST progress codes
(checkpoints)” on page 84.
2. If no entry is found, Replace the
system-board.
A05-10x System shutdown due to FRU that has
failed.
1. Check the BladeCenter management-module
event log; if an error was recorded by the
system, see “POST progress codes
(checkpoints)” on page 84.
2. If no entry is found, Replace the
system-board.
A05-14x System shutdown due to power fault
with an unspecified cause.
1. Check the BladeCenter management-module
event log; if an error was recorded by the
system, see “POST progress codes
(checkpoints)” on page 84.
2. If no entry is found, Replace the
system-board.
A05-19x System shutdown due to Fan failure.
1. Check the BladeCenter management-module
event log; if an error was recorded by the
system, see “POST progress codes
(checkpoints)” on page 84.
2. If no entry is found, Replace the
system-board.