Table 27. A00-FF0 through A24-xxx SRNs (continued)
SRN Description FRU/action
A0D-36x Other IPL Diagnostic Error.
1. Check the BladeCenter management-module
event log; if an error was recorded by the
system, see “POST progress codes
(checkpoints)” on page 84.
2. If no entry is found, Replace the
system-board.
A0D-37x Clock or PLL Error.
1. Check the BladeCenter management-module
event log; if an error was recorded by the
system, see “POST progress codes
(checkpoints)” on page 84.
2. If no entry is found, Replace the
system-board.
A0D-38x Hardware Scan or Initialization Error.
1. Check the BladeCenter management-module
event log; if an error was recorded by the
system, see “POST progress codes
(checkpoints)” on page 84.
2. If no entry is found, Replace the
system-board.
A0D-40x FRU Presence/Detect Error
(Mis-Plugged).
1. Check the BladeCenter management-module
event log; if an error was recorded by the
system, see “POST progress codes
(checkpoints)” on page 84.
2. If no entry is found, Replace the
system-board.
A10-100 The resource is unavailable due to an
error. System is operating in degraded
mode.
1. Check the BladeCenter management-module
event log; if an error was recorded by the
system, see “POST progress codes
(checkpoints)” on page 84.
2. If no entry is found, Replace the
system-board.
A10-200 The resource was marked failed by the
platform. The system is operating in
degraded mode.
1. Check the BladeCenter management-module
event log; if an error was recorded by the
system, see “POST progress codes
(checkpoints)” on page 84.
2. If no entry is found, Replace the
system-board.
A10-210 The processor has been deconfigured.
The system is operating in degraded
mode.
1. Check the BladeCenter management-module
event log; if an error was recorded by the
system, see “POST progress codes
(checkpoints)” on page 84.
2. If no entry is found, Replace the
system-board.
A11-00x A non-critical error has been detected.
Error log analysis indicates an error
detected by the microprocessor, but the
failure could not be isolated.
1. Check the BladeCenter management-module
event log; if an error was recorded by the
system, see “POST progress codes
(checkpoints)” on page 84.
2. If no entry is found, Replace the
system-board.
Chapter 2. Diagnostics 165