Table 27. A00-FF0 through A24-xxx SRNs (continued)
SRN Description FRU/action
A13-06x A non-critical error has been detected, a
mezzanine bus address parity error.
1. Check the BladeCenter management-module
event log; if an error was recorded by the
system, see “POST progress codes
(checkpoints)” on page 84.
2. If no entry is found, Replace the
system-board.
A13-07x A non-critical error has been detected, a
system bus address parity error.
1. Check the BladeCenter management-module
event log; if an error was recorded by the
system, see “POST progress codes
(checkpoints)” on page 84.
2. If no entry is found, Replace the
system-board.
A13-09x A non-critical error has been detected, a
system bus data parity error.
1. Check the BladeCenter management-module
event log; if an error was recorded by the
system, see “POST progress codes
(checkpoints)” on page 84.
2. If no entry is found, Replace the
system-board.
A13-11x A non-critical error has been detected, a
system bus time-out error
1. Check the BladeCenter management-module
event log; if an error was recorded by the
system, see “POST progress codes
(checkpoints)” on page 84.
2. If no entry is found, Replace the
system-board.
A13-12x A non-critical error has been detected,
an error on system bus.
1. Check the BladeCenter management-module
event log; if an error was recorded by the
system, see “POST progress codes
(checkpoints)” on page 84.
2. If no entry is found, Replace the
system-board.
A13-13x A non-critical error has been detected,
an I/O expansion bus parity error.
1. Check the BladeCenter management-module
event log; if an error was recorded by the
system, see “POST progress codes
(checkpoints)” on page 84.
2. If no entry is found, Replace the
system-board.
A13-14x A non-critical error has been detected,
an I/O expansion bus time-out error.
1. Check the BladeCenter management-module
event log; if an error was recorded by the
system, see “POST progress codes
(checkpoints)” on page 84.
2. If no entry is found, Replace the
system-board.
A13-15x A non-critical error has been detected,
an I/O expansion bus connection
failure.
1. Check the BladeCenter management-module
event log; if an error was recorded by the
system, see “POST progress codes
(checkpoints)” on page 84.
2. If no entry is found, Replace the
system-board.
170 Power Systems: Problem Determination and Service Guide for the IBM Power PS700 (8406-70Y)